序号负载功率(KW)额定电流(A)电缆选型参考型号12345678910111213141516171819202122230.11-0.550.751.11.52.2345.57.5111518.522303745557590110132160200<11.82.53.44.86.48.211.11522293842577084103139166203242292365KVV-4*1YJV-4*1.5YJV-4*1.5YJV-4*1.5YJV-4*1.5YJV-4*1.5YJV-4*2.5YJV-4*2.5YJV-4*4YJV-4*4YJV-3*6+1*4YJV-3*10+1*6YJV-3*10+1*6YJV-3*16+1*10YJV-3*25+1*16YJV-3*35+1*16YJV-3*50+1*25YJV-3*70+1*35YJV-3*95+1*50YJV-3*120+1*70YJV-3*150+1*70YJV-2(3*70+1*35)YJV-2(3*95+1*50)电缆最大载流量(A)红本价(元/米)222222222230304040526565851151451752202703203604405406.97.37.37.37.37.310.810.816.616.621.835.635.653.681.91051401962723414082*1942*272242525220250280410461515YJV-2(3*120+1*70)YJV-2(3*150+1*70)YJV-2(3*185+1*95)6106908602*3412*4082*51612345678303745557590110132如果是星角启动电机则按以下电缆选型57YJV-2(3*6+1*4)10470YJV-2(3*10+1*6)13084YJV-2(3*16+1*10)170103YJV-2(3*25+1*16)230139YJV-2(3*35+1*16)290166YJV-2(3*50+1*25)350203YJV-2(3*70+1*35)440242YJV-2(3*95+1*50)540控制电缆选KVV或KVVR多芯1.52*21.82*35.62*53.62*81.92*1052*1402*1962*272